H501-06 single-point weighing load cell by Bonida CNC

H501-06 Single-Point Weighing Load Cell

ISO 9001:2015 Certified
12-Month Warranty
Calibration Certificate
7-Day Sample Testing

Description

The Bonida H501-06 is a single-point weighing load cell for industrial weighing systems and equipment integration. Verified technical specifications (source catalog page 26): • Capacity: 150, 250, 500, 1000, 2000 kg • Rated output: 2.0 ±1% mV/V • Zero balance: ±1% mV/V • Creep: 0.02% F.S. • Non-linearity: 0.02% F.S. • Hysteresis: 0.02% F.S. • Repeatability: 0.01% F.S. • Input impedance: 380 ±15 Ω • Output impedance: 350 ±1 Ω • Temperature effect on sensitivity: 0.02% F.S./10°C • Temperature effect on zero: 0.02% F.S./10°C • Insulation resistance: ≥5000 MΩ/100 VDC • Recommended excitation: 5–12 V • Maximum excitation: 15 V • Compensated temperature range: -10 to 40°C • Operating temperature range: -20 to 65°C • Safe overload: 150% F.S. • Ultimate overload: 200% F.S. • Cable: 3 m • Material: Alloy steel Public pricing is not displayed. Please submit an RFQ to confirm the required capacity, quantity, integration details and lead time.